> HYDROGEN ANALOG CONTROL SIGNAL TRANSMITTER
 

HYDROGEN ANALOG CONTROL SIGNAL TRANSMITTER: S4H-Tx-01

 

INDUSTRIAL APPLICATION FOR LONG DISTANCE TRANSMISSION IN REFINERIES, PHARMACEUTICAL, CHEMICAL AND FERTILIZER PLANTS

 

 

S4H-Tx-01 is a Hydrogen control signal device for long range transmission of signal.
  • It is a transmitter device operating on 24V DC current loop for 4 to 20mA output signal.
  • It is designed to engage with user facilities for signal management and subsequent automation.
  • There are no alarm or relay contacts from the device.
  • The range for the span is pre-decided at the input stage, which is set at manufacture in accordance with user requirement. It is flexible for user calibration in-situ at sites of operation

 

SPECIFICATIONS OF HYDROGEN CONTROL SIGNAL TRANSMITTER
1
Input Signal
Two wire current signal (µA)
2
Input device
CHS-HTR-PH-100-2W in twin configuration (at distance ≤ 1 M) or Integral mounting
2
Max Negative offset I/P current
~ 20% of Span set.
3
Signal amp I/P current 
Max +/-10 Pa
4
Sensor Input Isolation Power
Galvanic isolation from the two wire loop 10 Mohm at 500V DC test voltage                                                     
5
Electrical Non- Linearity
1% of F.S.
6
Offset & Span drift
0.001% of reading/°C
7
Minimum operating Voltage
12V DC
8
Absolute Max. Operating Voltage
36V DC
9
Reverse polarity protection
Reverse Polarity Protected
10
Span & Zero Settings
4 mA and 20 mA currents can be set by presets R13 & R15 resp. 4 mA = ambient air & 20mA = span (N% H2 in air) N = 1 to 4 as ordered.
11
Termination used
Signal input on a Teflon block, Cable shield as a sensor ground. 
12
Calibration
By 4 position DIP switch + ENTER Key
13
Operating Temp.
0°C to +55°C
14
Humidity
98% RH at 40°C Non-condensing
15
Size
~ 90 mm (Dia) X 35 mm (H)
16
Enclosure
4 Port FLPE Junction Box
CMRICER No: CMRI/TC/P/H346
CAT No: TE/CP/02
Gas Group: Exia-IIC
Rating: 30A/415V
   Specification subject to changes without prior notice, due to continuous R&D and development of Company’s Products